Bod Incubator
Bod Incubator

Bod Incubator

Price 55000.0 INR/ Unit

MOQ : 1 Unit

Bod Incubator Specification

  • Automation Grade
  • Semi-automatic
  • Equipment Type
  • BOD Incubator
  • Resolution
  • 0.1C
  • Humidity
  • 50% to 90% RH
  • Number of Specimens
  • Multiple, as per rack capacity
  • Power Supply
  • 220 V AC, 50 Hz
  • Mounting Type
  • Floor standing
  • Application
  • Biochemical Oxygen Demand (BOD) determination, Environmental Laboratories, Research, and Microbiology
  • Operating Voltage
  • 220 V
  • Features
  • Auto temperature control, Uniform temperature, CFC free cooling system, Digital display
  • Frequency
  • 50 Hz
  • Temperature
  • 5C to 60C
  • Accuracy
  • 0.5C
  • Specimen Size
  • Standard BOD bottle (300 ml)
  • Max Height
  • 750 mm
  • Display Type
  • Digital
  • Usage
  • Incubation for BOD testing
  • Capacity
  • 6, 12, 24, or 36 bottles (various models)
  • Machine Weight
  • 90 kg
  • Control Mode
  • Microprocessor-based controller
  • Light Source
  • Optional
  • Cooling System
  • Hermetically sealed compressor, CFC free
  • Outer Chamber Material
  • Mild Steel, powder coated
  • Inner Chamber Material
  • Stainless Steel
  • Chamber Volume
  • 110-250 liters, as per model
  • Timer
  • 0-999 minutes (digital)
  • Air Circulation
  • Motorized blower
  • Shelves
  • Adjustable, Stainless steel
  • Insulation
  • High grade glass wool (65 mm)
  • Temperature Uniformity
  • 1C
  • Alarm System
  • Temperature deviation alarm
  • Door Type
  • Double walled insulated door with magnetic gasket
 

Bod Incubator Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 7 Days
 

Bod Incubator About

The BOD Incubator (Biochemical Oxygen Demand Incubator) is a precision laboratory instrument designed to maintain a controlled low-temperature environment for incubation of samples used in BOD testing and microbiological studies. It ensures stable temperature conditions required for accurate biological and environmental analysis.

This equipment is widely used in environmental laboratories, water treatment plants, research institutes, pharmaceutical industries, and food testing laboratories.


Key Features:

  • Digital Temperature Control: Microprocessor-based system for precise regulation
  • Uniform Cooling System: Ensures consistent temperature throughout the chamber
  • High-Quality Insulation: Minimizes heat loss and improves efficiency
  • Adjustable Shelves: Flexible storage for different sample sizes
  • Inner Glass Door (optional): Allows viewing without disturbing temperature
  • Sturdy Construction: Powder-coated or stainless steel interior options
  • Low Noise Operation: Suitable for continuous laboratory use

Working Principle:

The BOD Incubator maintains a constant low temperature (typically 20C 1C) required for measuring biochemical oxygen demand. This controlled environment allows microorganisms in the sample to decompose organic matter over a specific period, enabling accurate BOD analysis.


Applications:

  • Biochemical Oxygen Demand (BOD) testing
  • Wastewater and sewage analysis
  • Environmental monitoring
  • Microbiological culture growth
  • Pharmaceutical and food testing
  • Research and academic laboratories

Technical Specifications:

  • Temperature Range: 5C to 60C (typical range)
  • Control Accuracy: 0.5C to 1C
  • Capacity: 50 L to 400 L (or customized)
  • Display: Digital LED/LCD
  • Refrigeration System: CFC-free compressor
  • Insulation: PUF (Polyurethane Foam)
  • Power Supply: 220V AC, 50 Hz


Superior Temperature Control and Uniformity

The BOD Incubator employs a microprocessor-based system ensuring precise temperature regulation from 5C to 60C with 0.5C accuracy and 0.1C resolution. A hermetically sealed, CFC-free compressor and motorized blower provide uniform conditions, essential for reproducible BOD testing and reliable results.


User-Friendly, Robust Design

Designed for ease of use, the incubator features a digital display, auto temperature control, and a floor-standing structure with adjustable stainless steel shelves. Its double-walled insulated door with a magnetic gasket maintains internal stability, while high-grade glass wool insulation maximizes energy efficiency and performance.


Versatile Applications and Capacity

Ideal for environmental laboratories, research institutions, and microbiology applications, the BOD Incubator accommodates various specimen numbers-ranging from 6 to 36 standard BOD bottles-depending on the chosen model. The chamber volume is selectable between 110 and 250 liters, supporting both low- and high-throughput requirements.

FAQ's of Bod Incubator:


Q: How does the BOD Incubator maintain temperature uniformity?

A: The BOD Incubator ensures temperature uniformity within 1C using a microprocessor-based controller, hermetically sealed compressor, and a motorized blower for consistent air circulation throughout the chamber.

Q: What is the benefit of the double-walled insulated door with magnetic gasket?

A: This door design enhances thermal insulation, minimizes temperature fluctuations, and improves energy efficiency, ensuring stable internal conditions for accurate incubation.

Q: When should the temperature deviation alarm be used?

A: The temperature deviation alarm is critical during sensitive incubation processes. It activates whenever chamber temperature moves outside the preset limits, alerting users to take immediate action and preserve specimen integrity.

Q: Where is the BOD Incubator commonly used?

A: It is widely utilized in environmental laboratories, research institutes, and microbiology labs across India for BOD testing and incubating various biological specimens.

Q: What is the process for setting temperature and humidity in the BOD Incubator?

A: Users can easily set desired temperature (5C-60C) and humidity (50%-90% RH) through the intuitive microprocessor-based digital controller, ensuring optimal conditions for BOD analysis.

Q: How many specimens can be incubated at one time?

A: Depending on the chosen model, the incubator accommodates 6, 12, 24, or 36 standard 300 ml BOD bottles, with shelves adjustable to hold multiple samples as needed.

Q: What key features enhance the operational efficiency of this equipment?

A: Key features include auto temperature control, uniform cooling, a digital display, CFC-free cooling system, high-grade insulation, adjustable shelves, and a user-friendly interface, making it efficient for routine laboratory workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid mechanics lab equipment Category

RECIRC-ULATING TYPE JET APPARATUS

RECIRC-ULATING TYPE JET APPARATUS

Price 60000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Hydraulic engineering laboratory experiments

Mounting Type : Tabletop bench mounting

Power Supply : 230 V AC, 50 Hz

Usage : Study of the impact of jet and momentum transfer

Cleveland Flash And Fire Point Apparatus

Cleveland Flash And Fire Point Apparatus

Price 8000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Used to determine flash and fire point of petroleum products

Mounting Type : Benchtop

Power Supply : 230 V AC, 50 Hz

Usage : Laboratory instrument for petroleum testing

Redwood Viscometer Apparatus

Redwood Viscometer Apparatus

Price 10000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Measurement of kinematic viscosity of petroleum liquids

Mounting Type : Benchtop

Power Supply : 230V AC, 50 Hz (for water bath heating element)

Usage : Industrial laboratory, Educational demonstration

Hot Plates

Hot Plates

Price 3500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Heating, drying and laboratory experiments

Mounting Type : Bench Top

Power Supply : 230V AC, 50Hz

Usage : Laboratory, Industrial, Educational Institutions



Back to top