Cleveland Flash And Fire Point Apparatus
Cleveland Flash And Fire Point Apparatus

Cleveland Flash And Fire Point Apparatus

Price 8000.0 INR/ Unit

MOQ : 1 Unit

Cleveland Flash And Fire Point Apparatus Specification

  • Port Size
  • Standard gas inlet fitting
  • Humidity
  • Ambient
  • Features
  • Heavy duty construction, easy operation, corrosion-resistant finish
  • Measuring Range
  • Ambient to 370C
  • Temperature
  • Ambient to 370C (controlled via heating element)
  • Frequency
  • 50 Hz
  • Interface Type
  • Manual
  • Resolution
  • 0.1C
  • Gas Pressure
  • Regulated
  • Application
  • Used to determine flash and fire point of petroleum products
  • Accuracy
  • 1C
  • Operating Voltage
  • 230V AC
  • Equipment Type
  • Cleveland Flash and Fire Point Apparatus
  • Number of Specimens
  • Single vessel
  • Automation Grade
  • Manual
  • Test Range
  • Ambient to 370C
  • Response Time
  • Instantaneous on analog/digital gauge
  • Display Type
  • Analog or optional digital thermometer
  • Mounting Type
  • Benchtop
  • Max Height
  • 450 mm (approx)
  • Power Supply
  • 230 V AC, 50 Hz
  • Specimen Size
  • 70 mm inner diameter 50 mm depth (standard test cup)
  • Usage
  • Laboratory instrument for petroleum testing
  • Capacity
  • 150 ml test cup
  • Machine Weight
  • 10 kg (approx)
  • Test Speed
  • Manual operation
  • Test Width
  • Standard test vessel width
  • Control Mode
  • Manual
  • Ignition Source
  • Gas test jet and electric ignitor
  • Included Accessories
  • Thermometer, test jet assembly, draft shield
  • Heating Source
  • Electric heating element with variable temperature control
  • Stirring Mechanism
  • Manual or mechanical stirrer as per IS/ASTM standards
  • Material of Construction
  • Mild steel housing with powder coated finish, brass test cup
  • Safety Features
  • Thermal cut-off and fume vent
 
 

About Cleveland Flash And Fire Point Apparatus

The Cleveland Flash and Fire Point Apparatus is a precision laboratory instrument used to determine the flash point and fire point of petroleum products, lubricating oils, and other flammable liquids. It is designed for open cup testing of samples that have flash points above 79C, providing critical safety and quality information for handling and storage.

This apparatus is manufactured in compliance with ASTM D92 and IP 36 standards, ensuring accurate, reliable, and repeatable test results. It is widely used in petroleum refineries, oil testing laboratories, chemical industries, and quality control departments.


Key Features

  • Conforms to ASTM D92 / IP 36 standards
  • Open cup design for high flash point liquids
  • Precise temperature control system
  • Robust brass/stainless steel heating bath
  • Manual or digital temperature indication (optional)
  • Durable and corrosion-resistant construction

Applications

  • Petroleum product testing
  • Lubricating oil analysis
  • Fuel quality control
  • Chemical and solvent safety evaluation
  • Research and development laboratories

Technical Specifications (Typical)

  • Temperature Range: Ambient to 400C
  • Heating System: Electric heater with energy regulator
  • Test Cup: Standard Cleveland open cup
  • Ignition Source: Test flame applicator
  • Thermometer: ASTM/IP certified thermometer
  • Power Supply: 220240V AC, 50 Hz

Advantages

  • Accurate determination of flash and fire points
  • Reliable performance under high-temperature conditions
  • Strong and long-lasting construction
  • Easy operation for routine laboratory testing

Safety Note

Operate the apparatus in a well-ventilated area away from open flames. Always follow standard laboratory safety procedures when handling flammable liquids at high temperatures.



Durable Construction & Safety

Built with a powder-coated mild steel body and brass test cup, the apparatus resists corrosion and maintains structural integrity over prolonged use. It incorporates vital safety features, including a thermal cut-off and efficient fume vent, reducing operational risks during high-temperature tests. These measures ensure a safe and dependable environment for laboratory personnel conducting routine flash and fire point assessments.


Accurate & Flexible Heating Control

The Cleveland Flash and Fire Point Apparatus features an electric heating element with variable temperature control. Users can precisely adjust the temperature from ambient up to 370C, matching diverse testing requirements. The device accommodates both analog and optional digital thermometer displays for easy monitoring, ensuring accuracy of 1C and a resolution of 0.1C.


Versatile Operation & Easy Handling

With options for manual or mechanical stirring and single-vessel testing, the apparatus is well-suited for petroleum laboratories that require standardization and flexibility. The benchtop design and moderate weight (approx. 10 kg) enable easy placement and movement, while intuitive controls ensure straightforward operation for service providers, traders, suppliers, and manufacturers alike.

FAQ's of Cleveland Flash And Fire Point Apparatus:


Q: How do I operate the Cleveland Flash and Fire Point Apparatus for petroleum testing?

A: To operate the apparatus, place the petroleum sample in the brass test cup, set the temperature using the variable control, and initiate the test using manual or mechanical stirring according to IS/ASTM standards. Monitor the flash and fire point with the included thermometer and observe the test results on the analog or digital display.

Q: What materials are used in the construction of this flash and fire point apparatus?

A: The apparatus is constructed from mild steel with a powder-coated finish for durability and corrosion resistance, and the test cup is made from brass. This robust construction ensures longevity and reliability, even with frequent use in laboratory environments.

Q: When should I use the Cleveland Flash and Fire Point Apparatus?

A: Use this apparatus when testing the flash and fire points of petroleum products, which are critical when assessing safety and compliance in quality control, research, or routine laboratory analyses of fuels and oils.

Q: Where is the ideal setting to install and use this apparatus?

A: This instrument is designed for benchtop use in controlled laboratory environments. Ensure the area has access to a 230V AC power supply and standard gas inlet fitting, and is ventilated to handle fumes generated during testing.

Q: What is the process for determining flash and fire points with this device?

A: The process involves heating the petroleum sample in the test cup at a regulated rate, while stirring and introducing an ignition source via the gas test jet or electric ignitor. The flash point is recorded when vapors ignite momentarily; the fire point is noted when sustained burning occurs. Safety and accuracy are ensured throughout the process.

Q: How does the apparatus enhance testing safety and reliability?

A: Safety is enhanced with a built-in thermal cut-off to prevent overheating and a dedicated fume vent for hazardous gas management. The heavy-duty, powder-coated mild steel body and brass test cup further minimize risks and ensure dependable, long-term use.

Q: What are the benefits of using this Cleveland Flash and Fire Point Apparatus?

A: Benefits include precise measurement (accuracy: 1C, resolution: 0.1C), flexibility with manual or mechanical stirring, easy operation, and compliance with IS/ASTM standards, making it ideal for manufacturers, service providers, and laboratory professionals engaged in petroleum product quality testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid mechanics lab equipment Category

Bulk Density Apparatus

Bulk Density Apparatus

Price 15000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 1% of reading

Application : Determination of bulk density of powders and granules

Frequency : 50 Hz

Temperature : 10C to 40C

Pensky Martens Flash Point Apparatus

Pensky Martens Flash Point Apparatus

Price 10000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 0.5C

Application : For determining closed cup flash point of petroleum products

Frequency : 50 Hz

Temperature : Ambient to 400C (operating)

Laboratory Water Bath

Laboratory Water Bath

Price 5500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 1C

Application : Heating of samples in laboratory, incubation, chemical reactions

Frequency : 50Hz

Temperature : Ambient to 99C

Water Distillation Apparatus

Water Distillation Apparatus

Price 35000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : High purity distillate, low conductivity

Application : Production of distilled water for laboratory use

Frequency : 50 Hz

Temperature : Ambient to 100C



Back to top