Saybolt Furol Viscometer
Saybolt Furol Viscometer

Saybolt Furol Viscometer

Price 10000.0 INR/ Unit

MOQ : 1 Unit

Saybolt Furol Viscometer Specification

  • Frequency
  • 50 Hz
  • Specimen Size
  • 60 ml (oil cup volume)
  • Port Size
  • Standard oil cup orifice, as per ASTM D88 specifications
  • Max Height
  • Approx. 350 mm
  • Resolution
  • 1 sec
  • Interface Type
  • Mechanical
  • Number of Specimens
  • 1 per test
  • Power Supply
  • 230 V AC, 50 Hz
  • Application
  • Determination of viscosity of petroleum products
  • Measuring Range
  • Control based on efflux time (Saybolt Furol seconds, ASTM D88)
  • Mounting Type
  • Benchtop
  • Temperature
  • Ambient to 100C (controlled by heater and thermometer)
  • Features
  • Complete with oil cup, receiver flask, jet, thermometer, bath, electrical heater and insulated body
  • Automation Grade
  • Manual
  • Humidity
  • Ambient
  • Display Type
  • Analog
  • Operating Voltage
  • 230 V AC
  • Test Range
  • Fuels, lubricants and other petroleum products
  • Accuracy
  • 1 sec (efflux time)
  • Response Time
  • Real-time
  • Equipment Type
  • Saybolt Furol Viscometer
  • Usage
  • Laboratory/Industrial
  • Capacity
  • 1 sample/test
  • Machine Weight
  • Approx. 8 kg
  • Control Mode
  • Manual operation
  • Typical Accessories
  • Receiver, bath cover, thermometer, withdrawal tube
  • Heating Method
  • Immersion heater with adjustable regulator
  • Finish
  • Powder coated/Polished metal
  • Conforming Standard
  • ASTM D88, IP 13
  • Thermometer Range
  • 0C to 100C
  • Bath Material
  • Copper (oil bath), Stainless steel structure
  • Safety Feature
  • Thermal insulation and regulated heating
  • Orifice Diameter
  • 2.0 mm (as per ASTM D88)
 
 

Saybolt Furol Viscometer About

The Saybolt Furol Viscometer is a precision laboratory instrument used to determine the viscosity of heavy petroleum products, fuel oils, and bituminous materials. It measures the time required for a fixed volume of liquid to flow through a standard orifice under controlled temperature conditions, expressed in Saybolt Furol Seconds (SFS).

This apparatus is designed in accordance with ASTM D88 and IP 75 standards, ensuring accurate, reliable, and repeatable viscosity measurements. It is widely used in petroleum refineries, oil testing laboratories, and quality control departments.


Key Features

  • Conforms to ASTM D88 / IP 75 standards
  • Specifically designed for high-viscosity liquids
  • Precise temperature control system
  • Brass oil bath and standardized orifice jet
  • Digital or analog temperature display (optional)
  • Sturdy, corrosion-resistant construction

Applications

  • Heavy petroleum product testing
  • Fuel oil and bitumen viscosity analysis
  • Lubricant industry quality control
  • Refinery and petrochemical laboratories
  • Research and development facilities

Technical Specifications (Typical)

  • Temperature Range: Ambient to 200C (depending on model)
  • Heating System: Electric heater with energy regulator
  • Orifice Type: Standard Furol jet
  • Bath Medium: Oil bath
  • Thermometer: ASTM/IP certified thermometer
  • Power Supply: 220240V AC, 50 Hz

Advantages

  • Accurate measurement of high-viscosity samples
  • Reliable and repeatable test results
  • Robust design for industrial use
  • Easy operation and low maintenance

Safety Note

Handle hot oil baths with care. Ensure proper temperature control and follow standard laboratory safety procedures during operation.



Precise Viscosity Measurement

Engineered to conform with ASTM D88 and IP 13 standards, the Saybolt Furol Viscometer delivers consistent and precise viscosity data for petroleum products. Its single-sample capacity, controlled heating, and mechanical interface make it ideal for quality control labs and research facilities seeking reliable measurement of fuels and lubricants.


Robust and User-Friendly Design

Featuring stainless steel construction and a powder-coated or polished exterior, this viscometer is designed for long-lasting durability. A thermal-insulated bath and manual controls ensure both operator safety and operational convenience, supported by essential accessories such as a receiver flask, bath cover, and calibrated thermometer.


Versatile Laboratory Applications

With its analog readout, broad temperature range (ambient to 100C), and compatibility with standard oil cups per ASTM D88, this benchtop instrument is suited for routine viscosity testing in laboratory and industrial environments. Its straightforward manual operation and real-time response enable efficient and accurate sample analysis.

FAQ's of Saybolt Furol Viscometer:


Q: How is the Saybolt Furol Viscometer used to measure the viscosity of petroleum products?

A: The instrument measures viscosity by recording the efflux time for a 60 ml sample to flow through a standardized 2.0 mm orifice at controlled temperatures, as specified by ASTM D88. The analog display provides results in Saybolt Furol seconds, allowing for accurate assessment of fuel or lubricant viscosity.

Q: What safety features are incorporated into this viscometer?

A: The Saybolt Furol Viscometer is equipped with comprehensive thermal insulation and regulated heating, reducing the risk of burns or overheating and ensuring a safe environment for laboratory personnel during use.

Q: When should calibration of the instrument be performed?

A: Calibration should be performed before initial use and periodically as per laboratory quality standards, particularly if the viscometer is subjected to frequent use or after any maintenance that might affect measurement accuracy.

Q: Where is the Saybolt Furol Viscometer typically installed?

A: It is designed for benchtop installation in laboratory or industrial testing areas where viscosity measurements of petroleum products are routinely performed.

Q: What are the benefits of the copper oil bath and stainless steel structure?

A: The copper oil bath ensures rapid and even heating while maintaining accurate temperature control, and the stainless steel structure provides durability, corrosion resistance, and straightforward maintenance.

Q: What is the typical process for performing a viscosity test using this equipment?

A: A sample of 60 ml is placed in the oil cup, heated to the required test temperature using the immersion heater, and allowed to flow through the orifice. The efflux time is recorded, giving a direct viscosity value according to ASTM D88 protocols.

Q: How does manual control enhance usage of the Saybolt Furol Viscometer?

A: Manual operation allows the technician to finely adjust heating levels and monitor temperature, ensuring each test aligns precisely with standard methods, thus supporting repeatable and accurate results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid mechanics lab equipment Category

HELESHAW APPARATUS

HELESHAW APPARATUS

Price 50000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Demonstration of laminar and transitional flow, flow visualization studies, fluid mechanics education

Usage : Educational, laboratory flow visualization

Machine Weight : Approx. 18 kg

Measuring Range : Visualization of fluid fronts and interface

Temperature Humidity Chamber

Temperature Humidity Chamber

Price 70000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Environmental simulation, testing electronic and electrical components, stability test

Usage : Temperature and humidity reliability testing

Machine Weight : Approx 220 kg

Measuring Range : Temperature and Humidity as configured

HIGH SPEED STIRRER

HIGH SPEED STIRRER

Price 5500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Mixing, Stirring, Blending in laboratories & industries

Usage : Laboratory use, industrial batches

Machine Weight : 10 18 Kg

Measuring Range : 0 3000 rpm

PH Meter

PH Meter

Price 1000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Water and liquid pH measurement

Usage : Field and laboratory use

Machine Weight : 200 g

Measuring Range : 0.00 to 14.00 pH



Back to top