Vertical Autoclave Sterilizer
Vertical Autoclave Sterilizer

Vertical Autoclave Sterilizer

Price 10000.0 INR/ Unit

MOQ : 1 Unit

Vertical Autoclave Sterilizer Specification

  • Resolution
  • 1C
  • Hardness
  • Corrosion-resistant, rust-proof
  • Power Supply
  • 220 V AC, 50 Hz
  • Accuracy
  • 2C
  • Features
  • Double safety valve, pressure gauge, temperature controller, stainless steel construction, energy efficient
  • Response Time
  • Approx. 10 minutes to reach max temperature
  • Application
  • Sterilization of laboratory and medical instruments
  • Mounting Type
  • Floor Standing
  • Equipment Type
  • Vertical Autoclave Sterilizer
  • Frequency
  • 50 Hz
  • Operating Voltage
  • 220 V
  • Automation Grade
  • Semi-Automatic / Fully Automatic Available
  • Max Height
  • 900 mm
  • Humidity
  • Up to 85% RH
  • Display Type
  • Analog / Digital (optional)
  • Temperature
  • Up to 134C
  • Port Size
  • 1/2 inch
  • Usage
  • Laboratory, Hospital, Research Institutes
  • Capacity
  • 35 liters
  • Machine Weight
  • 85 kg
  • Control Mode
  • Manual / Automatic
  • Outer Body Material
  • Mild Steel with Powder Coating
  • Safety Features
  • Low Water Cut-Off, Automatic Pressure Release
  • Power Consumption
  • 2 kW
  • Heater
  • Immersion Type, 2 kW
  • Castor Wheels
  • Heavy-duty for mobility
  • Compliance Standard
  • ISI, CE Marked
  • Drain Valve
  • Fitted for easy draining
  • Insulation
  • Glass Wool
  • Sterilization Cycle Time
  • 30-60 minutes
  • Shape
  • Cylindrical
  • Lid Type
  • Radial Locking System with Neoprene Rubber Gasket
  • Chamber Material
  • Stainless Steel 304/316
  • Pressure Range
  • 15-20 psi (1.02-1.36 kg/cm2)
  • Water Level Indicator
  • Provided
 

Vertical Autoclave Sterilizer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
 

About Vertical Autoclave Sterilizer

The Vertical Autoclave Sterilizer is a highly efficient steam-based sterilization unit designed for safe and effective sterilization of laboratory instruments, culture media, glassware, and medical equipment. Using high-pressure saturated steam, it ensures complete elimination of bacteria, viruses, fungi, and spores.

Designed with a vertical chamber for space-saving installation, this autoclave is widely used in laboratories, hospitals, research centers, and pharmaceutical industries. Its robust construction and user-friendly operation make it a reliable solution for routine sterilization needs.

Key Features:

  • High-pressure steam sterilization system
  • Vertical, space-saving design
  • Durable stainless steel chamber
  • Precise temperature and pressure control
  • Safety features including pressure release valve and gasket locking
  • Available in manual, semi-automatic, and fully automatic models

Applications:

  • Microbiology and research laboratories
  • Hospitals and clinics
  • Pharmaceutical and biotech industries
  • Educational institutions
  • Food and beverage testing labs

Technical Specifications (Typical):

  • Capacity: 22 L to 100 L (customizable)
  • Working Temperature: Up to 121C 134C
  • Working Pressure: 1530 psi
  • Material: Stainless Steel (SS 304/SS 316)
  • Heating Type: Electric heating
  • Power Supply: 220240V AC, 50 Hz

Packaging Details:
Packed securely with protective materials to ensure safe transportation.

Usage Instructions:

  1. Load items to be sterilized into the chamber.
  2. Add required water level.
  3. Close lid securely and switch on the unit.
  4. Set desired temperature and time.
  5. Allow cycle completion and pressure release before opening.

Safety & Maintenance:

  • Do not open the lid under pressure
  • Regularly check gasket and valves
  • Clean chamber to avoid scaling and residue buildup


Robust Construction and Enhanced Safety

Crafted from high-quality stainless steel 304/316 and protected by a powder-coated mild steel outer shell, this vertical autoclave is built to resist rust and corrosion. The radial locking system, double safety valves, and low water cut-off features enhance safety and longevity. Glass wool insulation ensures energy efficiency and minimal heat loss, making it suitable for heavy laboratory or clinical use.


User-Friendly Operation and Flexible Control

This autoclave offers both manual and automatic modes to accommodate diverse operational needs. The analog or digital display options, water level indicator, and temperature controller provide precise control over each sterilization cycle. Its easy-drain valve and castor wheels add convenience, facilitating quick cleaning and mobility between workspaces in busy labs or hospitals.

FAQ's of Vertical Autoclave Sterilizer:


Q: How does the Vertical Autoclave Sterilizer maintain precise sterilization cycles?

A: The sterilizer uses an advanced temperature controller with 2C accuracy and 1C resolution, an optional digital or analog display, and immersion-type heaters. This allows for consistent sterilization cycles within 30-60 minutes at temperatures up to 134C and pressure ranges of 15-20 psi, ensuring reliable performance every time.

Q: What are the main benefits of the radial locking system with neoprene gasket lid?

A: The radial locking system provides a secure and uniform seal, preventing steam leakage and enhancing safety during operation. The neoprene rubber gasket ensures an airtight fit, ensuring optimal sterilization conditions and extended gasket life.

Q: When should the drain valve be used during the sterilization process?

A: After each sterilization cycle and once the chamber has cooled and depressurized, the fitted drain valve should be used to easily remove residual water. This helps maintain hygiene, prevents buildup, and prepares the chamber for the next cycle.

Q: Where can this Vertical Autoclave Sterilizer be effectively utilized?

A: This equipment is ideal for use in laboratories, hospitals, research institutes, and clinical facilities across India. Its mobility, durable design, and compliance with ISI and CE standards make it suitable for varied professional environments needing reliable sterilization.

Q: What safety features are included to protect users and equipment?

A: Safety is prioritized with features such as double safety valves, a low water cut-off system to prevent dry heating, and automatic pressure release. Additionally, the stainless steel construction offers durability and rust-resistance.

Q: How does the autoclave support both semi-automatic and fully automatic use?

A: The control mode can be configured for either manual or automatic operation. This flexibility allows users to choose between hands-on cycle management or automated, preset programs, catering to the workflow of laboratories or hospitals and enhancing user convenience.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Concrete Testing Lab Equipments Category

Ultrasonic Testing Machine

Ultrasonic Testing Machine

Price 120000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Control Mode : Digital Microprocessor Based

Application : Flaw detection, material thickness measurement, weld inspection

Capacity : Max. 1000 test data storage

Accuracy : 0.1 mm

Briquette Mould (Single)

Briquette Mould (Single)

Price 4000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Control Mode : Manual operation

Application : Preparation of cement mortar briquettes for tensile strength tests

Capacity : Single Briquette

Accuracy : Depends on dimensional tolerance

Shrinkage Bar Mould

Shrinkage Bar Mould

Price 3000.0 INR / Set

Minimum Order Quantity : 1 Set

Control Mode : Manual

Application : Used for preparing cement mortar bars for shrinkage test

Capacity : 3 compartments

Accuracy : High dimensional tolerance

Compaction Factor Apparatus

Compaction Factor Apparatus

Price 17000 INR / Piece

Minimum Order Quantity : 1 Piece

Control Mode : Manual

Application : Workability test of concrete

Capacity : 15 L (Cylinder Volume)

Accuracy : Compliant to IS 1199



Back to top